Open Source Free Energy & Over Unity Forums...and If You think none of these terms are real, they do not exist, or is just fiction, then PLEASE>>DO NOT ENTER!!



Free Energy will change the World - Free Energy will stop Climate Change-Free Energy will give us hope,
and we will not surrender until free energy will be enabled all over the world, to power planes, cars, ships and trains.
Free energy will help the poor to become independent of needing expensive fuels.
So all in all Free energy will bring far more peace to the world than any other invention has already brought to the world.
Words from Stefan Hartmann/Owner/Admin of Overunity Forum
I really love those words from Stefan, reason why they are here..
Overunity.com Forum is online at Overunity.com Archives

FIGUERA'S AETHER MAGNETIC FIELDS LINEAR PUMP, REVIVED

Started by Ufopolitics, Nov 19, 2023, 03:39 PM

Previous topic - Next topic

0 Members and 564 Guests are viewing this topic.

Ufopolitics

Hello dear friend @kampen ,

That's great to see you are making more testings!!

But please, when you are presenting a Test, provide FIRST ALL Components Present, AS the Components NOT PRESENT on the Test.

So, on your post, I had to keep reading all the way through, to find out that you do not have present the Main Center Secondary.

I hope that you have used a specific SPACER (in the PLACE of Main Secondary Coil) as to keep ALL Five Coils at EQUAL DISTANCES from Steel Core.

ABOUT THE HALL SENSORS

It is a very innovative idea to add Two Hall Sensors at each end of the Steel Core...

However, Hall Sensors use very small voltage (if there are not amplifiers present) As they are good to detect the STRENGTH of the Magnetic Field (once Output V is converted into Flux Density)

BUT, besides that issue, by connecting the Hall Sensors to directly the Steel Core, you are only showing the Steel Core Signals which typically are weak...

What makes the FULL INDUCED Magnetic Signal is ONLY through the Secondary Coils on ANY Generator, NOT on the Steel Core.

FEEDING A PULSE TO FC1 & FC2??!!

Then I read that Guido is also adding Pulsing Voltage to FC1 & FC2???!!!

FC1 & FC2 are NOT Coils to be pulsed!

FC1 & FC2 are SECONDARIES, SAME WAY AS the NOT PRESENT Main Center Secondary.

The ONLY Difference between FC1 & FC2 Secondaries is that their Output is ALTERNATED.

I have already discussed this issue with you previously...that FC1 & FC2 are NOT to be fed with anything, ANY KIND of POWER!!

ACTUALLY, instead of Hall Sensors, you can use FC1 & FC2 as Output Voltage Real Components to then convert into Flux Density and Field Strength...

HOWEVER. make sure that INNER STEEL PLATES, RIGHT & LEFT ARE INSTALLED when running this Test again, or:

[FC1] [Left Inner Steel Plate] [Q1][Q3][Q2] [Right Inner Plate] [FC2]

Then pulse ONLY Q1 & Q2, while providing Q3 of a CONSTANT (NOT PULSED) DC POWER.

MAKING INDIVIDUAL OUTPUT TESTS ON FC1 & FC2

Now you could make TWO INDIVIDUAL TESTS FIRST to know each FC Coil MIN-MAX Output Independently:

  • FC1 TEST= Apply Continuous DC Power to Q3, while JUST PULSING Q1, then measure FC1 Output V & A (A by loading it, of course)
  • FC2 TEST= Apply Continuous DC Power to Q3, while JUST PULSING Q2, then measure FC2 Output V & A (A by loading it, of course)
  • Record their INDEPENDENT Output Sinewaves and print them to show it as part of RESULTS.
  • It would be great if you could put BOTH SINES IMAGES from FC1 & FC2 as Transparencies showing both signals on a Voltage Versus Time Graph.
  • These TWO Images will show their TIMING DIFFERENCE as they are a result of ALTERNATED INDUCTION.

Then ADD IN SERIES FC1 & FC2 Coils and PULSE Q1 & Q2.

Compare Results with previous INDIVIDUAL TESTS...

FINALLY, Can you please use LOWER PULSES?

LIKE 60 HERTZ?

AND, Please, Alex, make these Tests above, WITHOUT Hall Sensors Present!

These Tests above will give us a TRUE OUTPUT READING ON V&A related to ONLY FC1 & FC2 Output...since Main Center Secondary is not present.

Again, I really appreciate all the time and work that you and Guido are putting into this project!!

Regards

Ufopolitics
Principles for the Development of a Complete Mind:Study the science of art. Study the art of science.
Develop your senses- especially learn how to see. Realize that everything connects to everything else.
―Leonardo da Vinci

kampen

Reply to Message #945 – Clarification of Hall Sensor Tests and Proposed FC1/FC2 Output Measurements

Hello, dear friend Ufopolitics,

Thank you very much for your detailed response, your continued guidance, and your appreciation of the work Guido Electronicus and I are doing.
I understand your concerns, and I would like to clarify a few important points regarding Guido's recent measurements.

1. Components present during the Hall sensor experiments:
You are absolutely right that we should clearly identify which components are installed and which are absent before presenting any experimental results.
I apologize for not making this sufficiently clear in my previous message.
The measurements I shared were intended primarily as diagnostic tests to investigate the magnetic field behavior of our existing laminated steel core, rather than as a complete SSD generator performance test.
The Main Secondary Center Coil was not installed during these measurements.
Regarding your question about a spacer maintaining the correct distances between the five coils, I will verify the exact mechanical arrangement with Guido rather than give you an unconfirmed answer.
I will also confirm the position of the inner steel plates during these tests.
For future reports, we will clearly document the complete mechanical configuration, electrical connections, components present or absent, and measurement conditions.

2. Hall sensor measurements:
Thank you for your comments concerning the Hall sensors.
Our intention was NOT to use their signals as a substitute for measuring the actual induced electrical output of the secondary coils.
We wanted to observe the local magnetic field response at both ends of the steel core while different coils were excited.
We understand that the Hall sensor output voltages must first be calibrated and converted into magnetic flux density before quantitative comparisons can be made.
We also agree that the most important measurements for evaluating the SSD generator are the actual induced Voltages and currents delivered by its secondary windings.
Therefore, we will keep the Hall sensor experiments separate from the proposed FC1 and FC2 output tests.

3. Important clarification regarding FC1 and FC2:
I fully understand your instruction that FC1 and FC2 must function as secondary output coils and must not be externally powered during the intended SSD generator operation.
I apologize that my previous description caused confusion.
Guido's individual coil-pulsing measurements were exploratory magnetic characterization tests, intended to observe the Hall sensor responses at the ends of the steel core.
They were NOT intended to represent the final SSD operating configuration.
Nevertheless, I agree that we should now concentrate on the correct arrangement, with Q1 and Q2 as the switched primary coils, Q3 supplied with constant DC bias, and FC1 and FC2 used exclusively as induced output coils.

4. Your proposed FC1 and FC2 output tests:
Your proposed procedure is clear, and I believe it gives us a useful next step.
We will discuss the following sequence with Guido:
Test A – Individual FC1 output
  • Apply constant DC current to Q3.
  • Pulse Q1 only.
  • Leave Q2 unpowered.
  • Measure the induced FC1 voltage under a known resistive load.
  • Record the FC1 voltage waveform and delivered output power.
Test B – Individual FC2 output
  • Maintain the same Q3 DC bias.
  • Pulse Q2 only.
  • Leave Q1 unpowered.
  • Measure the induced FC2 voltage under an equivalent resistive load.
  • Record the FC2 voltage waveform and delivered output power.
Test C – Combined FC1 and FC2 output
  • Connect FC1 and FC2 in series, after checking their winding polarities.
  • Pulse Q1 and Q2 alternately.
  • Maintain constant DC bias on Q3.
  • Measure the combined output voltage, load current and delivered power.
  • Compare the results with the individual FC1 and FC2 measurements.


We will also attempt to display the FC1 and FC2 waveforms on a common time axis so that their relative timing and polarity can be compared.
As you requested, these tests will be performed without the Hall sensors installed.
We will ensure that the two inner steel plates are correctly positioned:
FC1 – Left Inner Steel Plate – Q1 – Q3 – Q2 – Right Inner Steel Plate – FC2
The outer mechanical clamps will also be documented.

5. Testing at 60 Hz:
Thank you for suggesting a lower switching frequency.
We will include 60 Hz in the proposed test procedure, using the same defined Q3 bias and comparable loading conditions.
We can then compare the results with our previous 120 Hz measurements.
It will be particularly interesting to observe whether the lower frequency allows more complete current decay between pulses and how this influences the induced output waveforms.

6. SSD Testbench 2:
We are continuing preparations for our completely separate SSD Testbench 2, including the shortened Main Secondary Center Coil and corrected 1–1–1 geometry.
Our existing Testbench 1 will remain intact as a reference.
I believe it is sensible to perform your proposed FC1 and FC2 measurements on the existing arrangement first, provided Guido confirms that the required coil positions and inner steel plates are correct.
This would allow us to collect useful additional reference data before evaluating the new Main Secondary on Testbench 2.

7. One additional request concerning your simulations:
Dear Ufopolitics, Guido and I would still greatly appreciate any representative simulation waveforms or magnetic field distribution images you could share.
In particular, it would help us to know the expected current waveforms, Q3 bias conditions, switching frequency, and relative timing of the induced FC1 and FC2 voltages.
This would allow us to compare our experimental measurements directly with your predicted behavior.
We want to make sure that our next tests are performed in the operating region you intended, rather than continuing with trial-and-error adjustments.

Thank you again for your patience, your technical explanations, and your continued support.
Guido and I remain committed to carrying out careful, reproducible experiments and sharing the results openly.

Best regards,
Alex / Kampen
Together with Guido Electronicus
Dreams for the future.
Impossible is possible 👽

Ufopolitics

Hello dear friend @kampen ,

Ok, so it is great that we have a FULL & CLEAR understanding about the following tests!!

Want to thank again the excellent work you and Guido are doing here!!

Now, I did some Diagrams about your future Tests, measuring FC1 & FC2 Outputs (plus some extra check ups I would like to verify):


TESTING_FC1_OUTPUT_1_&_2.png

So, above is the Diagram to check FC1 Output ONLY.

Now, the setup remains the same, EXCEPT that Q2 is NOT BEING PULSED, NOR FED ANY POWER.

  • Q3 is ON ALL TIME during the testing by PSU-Q3
  • Q1 is PULSED from SSD- Q1 (And here I assumed you are pulsing ONLY Negative - with NFET's- side, while High Side (Positive) is continuous)

Then related to the way Magnetic Field should be generated:

  • Whenever Q1 Negative Pulsed Signal is at PEAK (Top) then Q1 Field should be at MAX Strength, like shown on image
  • While Q3 Field is FIXED at the same Strength ALL Times.

Now, there is a very IMPORTANT observation that I have noticed on ALL these Systems:

Whenever we have SERIES CONNECTED COILS in a LINEAR SETUP...I noticed their Fields -on each coil- REMAIN SEPARATED related to Magnetic Polarization.

  • Meaning that EACH COIL KEEPS its INDEPENDENT N/S FIELD Arrangement (like shown on image)
  • This is absolutely NOT GOOD for what we are looking for!!

We are looking for a COMPLETE FIELD FUSION between Q1 & Q3, that should look like below image (No matter if BOTH Fields are generated by SEPARATED SOURCES,)

The Magnetic Field SHOULD FUSE as a FULL  SINGLE FIELD, whenever the TWO COILS are ON and at Max Power, like shown below:


TESTING_FC1_IDEAL_FIELD.png

I have done these testings with my Magnetic Polarity Pen, by running it LINEARLY from Coil to Coil...

However, if I look at the Series Connected and POWERED Group of Coils with my Magnetic Viewing Film, then it shows as a UNIFIED/FUSED FIELD.

And honestly, it MUST give the same results with the Polarity Pen Tool...and NOT SHOWING A FRACTION-INDEPENDENT Field per Coil.

Although, I am sure that we are having an ATTRACTION CHAIN here...what am worried about is that the SUMM OF ALL COILS increase the FIELD STRENGTH.

So, going back to this Tests, I would like to READ POLARITIES FIRST, PLUS FIELD STRENGTH, by FEEDING FIRST Q1 with a CONTINUOUS DC Voltage, while Q3 is ON.

Then we do it AGAIN, while Q1 is being pulsed.

And here comes a very interesting behavior of Magnetic Fields on these Type of Generating Systems:

  • Field tends to REACH A MAX Strength, MAX Volumen at LOWER FREQUENCIES, like 60 Hertz.
  • Then, when we increase Frequencies, the Reaching of MAX Volumes & MAX Strength LOWERS ITS LEVELS CONSIDERABLY.
  • And these reflects clearly on our Output Spec's (Total Output)

RELATED TO FC1 OUTPUT TESTING:

On this Diagram, below FC1, I have set TWO TESTS MEASUREMENTS to be performed:

  • TEST 1= OPEN VOLTAGE (meaning NOT LOADED) just the Voltmeter connected on the OPEN FC1 COIL Terminals.
  • TEST 2 = LOADED VOLTAGE PLUS AMPERAGE (shown with a small Resistor and an AMMETER IN SERIES to FC1 Output Terminals .

Now, it is understood that Testing FC2 Output would be the COMPLETE OPPOSITE of this Test:

  • Pulsing Q2
  • While Q3 is ON all time with DC
  • Q1 is completely OFF

Regards and thanks so much for your great contributions for ALL of us here!!

Ufopolitics

EDIT 1: I believe I do have a 'Solution' for this Field behavior, but I rather make these testing before explaining the new method...as GEOMETRY for Coils would be completely different.
Maybe we will get pretty good results as System is Set now (related to Coil Configuration) ...
I do NOT like to complicate things before running these tests.
Principles for the Development of a Complete Mind:Study the science of art. Study the art of science.
Develop your senses- especially learn how to see. Realize that everything connects to everything else.
―Leonardo da Vinci

Ufopolitics

Hello ALL,

Hello dear friend,

Ok, so here is the FC2 OUTPUT TESTING DIAGRAM:

TESTING_FC2_OUTPUT.png

So, as I mentioned before, it is the complete opposite of previous drawing.

Here we have:

  • Q1 OFF
  • Q3 ON ALL TIME BY PSU-Q3
  • Q2 PULSED by SSD-Q2 (Neg side -dotted connected line)

Same TWO TESTS on OUTPUT:

  • TEST 1: NO LOAD, OPEN VOLTAGE
  • TEST 2: LOADED, Measuring V & A

Then we just need to CONNECT IN SERIES FC1 & FC2 then MEASURE THEIR TOTAL OUTPUT.

And here, we will know IF WE ARE CONNECTING PROPERLY THEIR TERMINALS, IN SERIES, SIMPLY BY SEEING THAT:

  • Total OPEN Voltage is BELOW what the TOTAL SUM of BOTH INDIVIDUAL TESTS SHOWED
  • The TOTAL MUST BE the EXACT ADDITION from BOTH FC1 & FC2 INDEPENDENT Coils results.

I have done this...and if we do not connect them properly in series, the Total amount would be similar to just One Output Coil.

Regards

Ufopolitics


Principles for the Development of a Complete Mind:Study the science of art. Study the art of science.
Develop your senses- especially learn how to see. Realize that everything connects to everything else.
―Leonardo da Vinci

kampen


Reply to Message #948 – FC2 Output Testing and Combined FC1/FC2 Measurements

Hello, dear friend Ufopolitics,

Thank you very much for your latest message and the additional FC2 output testing diagram.
Your explanations and the two drawings for FC1 and FC2 have made the proposed testing procedure much clearer for Guido Electronicus and me.
I appreciate the time you have taken to prepare these illustrations and explain the magnetic field arrangement you expect to obtain.

1. FC2 individual output testing:
I fully understand that the FC2 test is the mirror image of the previously proposed FC1 test.
The operating conditions will be:
  • Q1: Completely OFF, without any electrical power.
  • Q3: Continuously energized with constant DC bias from its separate power supply.
  • Q2: Pulsed through our SSD switching circuit.
  • FC2: Used exclusively as an induced secondary output coil, without any external electrical excitation.

As you requested, we will discuss performing two separate measurements with Guido:
Test 1 – Open-circuit voltage:
Measure the induced voltage across FC2 without connecting an external load, and record its voltage waveform.
Test 2 – Loaded output:
Connect a known resistive load across FC2 and measure both voltage and current to determine the actual electrical power delivered to the load.
We will apply the same measurement procedure to FC1, using Q1 excitation while Q2 remains OFF.

2. Comparing the FC1 and FC2 output waveforms:
Your suggestion to compare the two individual output waveforms is particularly useful.
We intend to record the FC1 and FC2 voltage signals with a common timing reference so that their polarity, amplitude, and relative timing can be examined.
This should help us understand how the alternating excitation of Q1 and Q2 influences the induced voltages in the two feedback coils.

3. Connecting FC1 and FC2 in series:
After completing the individual tests, we will investigate the combined output with FC1 and FC2 connected in series.
We understand your intention that the induced Voltages should reinforce each other rather than cancel.
Before making the final series connection, we will verify the winding polarities and voltage waveforms.
One technical point we would like to examine carefully is that the total instantaneous series voltage depends on the relative polarity and timing of the two induced waveforms.
If their Voltage peaks occur at different moments, the maximum combined voltage may not equal the arithmetic sum of the two separately measured peak voltages.
Therefore, we intend to compare the actual combined waveform with the individual FC1 and FC2 signals.
This will allow us to determine experimentally whether the two outputs are adding as intended.

4. Magnetic field fusion and polarity:
We have also taken note of your earlier explanation concerning the desired magnetic field fusion between Q1 and Q3, and subsequently between Q3 and Q2.
Guido has already performed some interesting Hall sensor measurements along our existing laminated steel core.
We would like to use these observations, together with your proposed output tests, to investigate the relationship between coil polarity, magnetic field distribution, and induced output Voltage.
We understand that your drawings represent the magnetic field configuration you are aiming to achieve.
Our next objective is to determine whether the actual measured behavior corresponds to this proposed arrangement.

5. Testing at 60 Hz:
We have also noted your recommendation to begin at the lower switching frequency of 60 Hz.
I will discuss this with Guido and compare the results with our earlier 120 Hz measurements, while documenting the actual coil currents, pulse duration, Q3 bias and output loading.

6. Coordination with Guido:
I have forwarded your latest instructions and diagrams to Guido Electronicus for his technical assessment.
Before proceeding, we will confirm the exact mechanical arrangement, including the positions of the inner steel plates, and verify that our switching circuit corresponds to the assumptions in your drawings.
We will also determine which measurements can be performed on our existing Testbench 1 without disturbing its reference configuration.
Our new SSD Testbench 2 remains a separate project, incorporating the shortened Main Secondary Center Coil and the corrected 1–1–1 arrangement.

Dear Ufopolitics,
Thank you again for your patience, encouragement, and continued technical guidance.
We appreciate your willingness to share your experience and help us develop a more systematic testing procedure.

I believe these individual FC1 and FC2 output measurements will provide useful experimental information about the actual magnetic coupling and induced electrical output.

Once Guido has reviewed the procedure and we have completed the measurements, I will share the results with you for further discussion.

Best regards,
Alex / Kampen
Together with Guido Electronicus
Dreams for the future.
Impossible is possible 👽


Open Source Free Energy-Over Unity Systems Research/Development/Disclosure/Discussions